Coagulation Control AK [CE]
Control plasma for use as an accuracy control for oral anticoagulant therapy monitoring. The plasma is prepared from donors who had been on long-term anticoagulant therapy and therefore contains PIVKA proteins. The plasma is externally calibrated for most thromboplastins.

TECHNOVIEW Arixtra*
|
|
5011050 5011060 |
5 x 1 mL 50 x 1 mL |

|
 | |
|
TECHNOVIEW Arixtra®* Calibrator Set [CE]
TECHNOVIEW Arixtra® Calibrator is a set of 5 calibrators (different concentrations between ~0-2 µg/mL) of Arixtra® (Fondaparinux sodium) measurements, titrated and optimised using anti-Xa assays. |
|
5090010 |
5 x 1 mL |
 |
 | |
|
TECHNOVIEW Arixtra®* Calibrator Kit [CE]
TECHNOVIEW Arixtra® Calibrator Kit is a set of 2 calibrators (CAL 1 at 0 µg/mL and CAL 5 at ~ 2 µg/mL) of Arixtra® (Fondaparinux sodium) measurements, titrated and optimised using anti-Xa assays Arixtra® can be used as an anticoagulant for curative or preventive indications. Measuring the Arixtra concentration in patient's plasma allows monitoring the therapy and adjusting drug dosage.
 |
|
5090011 |
2 x 1 mL |
 |
 | |
|
TECHNOVIEW Arixtra®* Controls [CE]
Control Plasma for the quality control of Arixtra® (Fondaparinux sodium) measurements, titrated and optimised using anti-Xa assays. Arixtra® can be used as an anticoagulant for curative or preventive indications. Measuring the Arixtra concentration in patient's plasma allows monitoring the therapy and adjusting drug dosage.
TECHNOVIEW Arixtra®* Low Control: ~ 0.5 µg/mL TECHNOVIEW Arixtra®* High Control: ~ 1.5 µg/mL

* Arixtra® is a registered trade mark of Glaxo Smith Kline
TECHNOVIEW LMW
|
|
Low Control
5090012
High Control
5090014
|
6 x 1 mL
6 x 1 mL |

 |

 | |
|
TECHNOVIEW LMW Calibrator Set [CE]
TECHNOVIEW LMW Calibrator Set is a set of 5 calibrators (different concentrations ~ 0-1.5 U/mL) of Low Molecular Weight (LMW) Heparin for the use in chromogenic heparin assays. Heparin is the most frequently used antithrombotic therapeutic drug. |
|
5090040 |
5 x 1 mL |
 |
 | |
|
TECHNOVIEW LMW Calibrator Kit [CE]
TECHNOVIEW LMW Calibrator Kit is a set of 2 calibrators (CAL 1 at 0 IU/mL and CAL 5 at ~ 1.6 IU/mL) of low molecular weight heparin for the use in chromogenic heparin assays. Heparin is the most frequently used antithrombotic therapeutic drug. The biological activity of this sulfated glycosaminoglycan resides in its ability to accelerate (up to 2000-fold) the inhibitory effect of antithrombin (AT) on the coagulation proteases.
|
|
5090041 |
2 x 1 mL |
 |
 | |
|
TECHNOVIEW LMW Controls [CE]
Control plasma for the quality control of heparin measurements. They are intended for the assessment of precision and accuracy. The Low, Medium and High Levels of Control Plasma of Low Molecular Weight (LMW) Heparin are containing different levels of LMW Heparin.
TECHNOVIEW LMW Low Control: ~ 0.3 -0.4 U/ml TECHNOVIEW LMW Medium Control: ~ 0.8 -0.9 U/ml TECHNOVIEW LMW high Control: ~ 1-1.2 U/ml

TECHNOVIEW UFH
|
Low Control
5090042
Medium Control
5090044
High Control
5090046
|
5 x 1 mL
5 x 1 mL
5 x 1 mL |


 |



| |
|
TECHNOVIEW UFH Calibrator Set [CE]
TECHNOVIEW UFH Calibrator Set is a set of 5 calibrators (different concentrations ~ 0-1.5 IU/mL) for calibration and the quality control of unfractionated Heparin (UFH) measurements titrated and optimised using anti-Xa assays. |
5090070
|
5 x 1 mL
|
|
 | |
|
TECHNOVIEW UFH Calibrator Kit [CE]
TECHNOVIEW UFH Calibrator Kit is a set of 2 calibrators (CAL 1 at 0 IU/mL and CAL 5 at ~ 1.40 IU/mL) for calibration of unfractionated Heparin (UFH) measurements titrated and optimised using anti-Xa assays.
|
5090071
|
2 x 1 mL
|
|
 | |
|
TECHNOVIEW UFH Controls [CE]
TECHNOVIEW UFH Control Plasma is a set of low and high control plasmas for the quality control of unfractionated Heparin (UFH) measurements.
TECHNOVIEW UFH Low Control: ~ 0.2 IU/ml TECHNOVIEW UHF high Control: ~ 0.5 IU/ml
 TECHNOVIEW Orgaran*
|
|
Low Control
5090072
High Control
5090074 |
5 x 1 mL
5 x 1 mL
|
|

 | |
|
TECHNOVIEW Orgaran®** Calibrator Set [CE]
TECHNOVIEW Orgaran® Calibrator Set is a set of 5 calibrators (different concentrations ~ 0-1.6 IU/mL) for calibration of Sodium Danaparoid (Orgaran®) measurements titrated and optimised using anti-Xa-assays.
|
|
5030110 |
5 x 1 mL
|
|
 | |
|
TECHNOVIEW Orgaran®** Calibrator Kit [CE]
TECHNOVIEW Orgaran® Calibrator Kit is a set of 2 calibrators (CAL 1 at 0 IU/mL and CAL 5 at ~ 1.6 IU/mL) for calibration of Sodium Danaparoïd (Orgaran®) measurements titrated and optimised using anti-Xa assays.
|
|
5030111 |
2 x 1 mL
|
|
 | |
|
TECHNOVIEW Orgaran®** Controls [CE]
TECHNOVIEW Orgaran® Control Plasma is a set of low and high control plasmas for the quality control of Sodium Danaparoid (Orgaran®)
TECHNOVIEW Orgaran® Low Control: ~ 0.5 IU/ml TECHNOVIEW Orgaran® high Control: ~ 1.0 IU/ml

**Orgaran® is a registered trade mark of Schering-Plough
TECHNOVIEW Rivaroxaban
|
|
Low Control
5090112
High Control
5090114 |
5 x 1 mL
5 x 1 mL
|
|

 | |
|
TECHNOVIEW Rivaroxaban*** Calibrator Set [CE]
TECHNOVIEW Rivaroxaban Calibrator Set are two sets of calibrators (different concentrations) for calibration of Rivaroxaban measurements titrated and optimised using anti-Xa assays. Rivaroxaban is an oxazolidinone derivative directly inhibiting FXa.
TECHNOVIEW Rivaroxaban CAL High Set ~ 0-500 ng/mL TECHNOVIEW Rivaroxaban CAL Set ~ 0-150 ng/mL
|
|
Calibrator Set
5090170
Calibrator CAL High Set
5090171
|
5 x 1 mL
5 x 1 mL
|
|

 | |
|
TECHNOVIEW Rivaroxaban*** Controls [CE]
TECHNOVIEW Rivaroxaban Control Plasma is a set of low, medium and high control plasmas for the quality control of Rivaroxaban
TECHNOVIEW Rivaroxaban Low Control: ~ 60 ng/ml TECHNOVIEW Rivaroxaban Medium Control: ~ 150 ng/ml TECHNOVIEW Rivaroxaban High Control: ~ 300 ng/ml

*** Rivaroxaban is the active substance in Xarelto® which is a registered trade mark of Bayer |
|
Low Control
5090172
Medium Control
5090173
High Control
5090174
|
5 x 1 mL
5 x 1 mL
5 x 1 mL
|
|



| |